| Components |

| 1. EGR cooler pipe C 2. Electric EGR (EEGR) control valve 3. EGR cooler | 4. EGR cooler pipe A 5. Gasket 6. EGR cooler pipe B |
Removal and Installation1.Disconnect the battery negative terminal.2.Remove the air cleaner assembly.(Refer to Intake and Exhaust System - "Air Cleaner")3.
Description and Operation
InspectionOperating Logic Test (Manual only)Inspect the PTC operation by confirmation logic as follows.1.Entering(1)Set the Floor mode and maximum heating position.(2)Turn off the blower switch.(3)Press the intake (recirculation) button 5 times or more.
Inspection1.Turn the ignition switch OFF.2.Disconnect the temperature control actuator connector.3.Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.Verify that the temperature control actuator operates to the warm position when connected in reverse.