| Replacement |
|
| 1. | Close the sunroof glass completely by pressing the sunroof switch. |
| 2. | Loosen the mounting screws (A) and remove the sunroof glass (B).
|
| 3. | To install, reverse the removal procedure.
|
Components Location1. Sunroof glass
Replacement1.Open the glass fully.2.Remove the mounting pins (C), from the frame (B), and then remove the deflector (A).3.To install, reverse the removal procedure.
DescriptionThe ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.The sensor output will be used for discharge temperature control, temperature regulation door contrl, blower m
InspectionOperating Logic Test (Manual only)Inspect the PTC operation by confirmation logic as follows.1.Entering(1)Set the Floor mode and maximum heating position.(2)Turn off the blower switch.(3)Press the intake (recirculation) button 5 times or more.