| Components |

| 1. Memory power seat unit (PSM) 2. IMS control switch | 3. Outside Mirror |
Specifications[Memory Power Seat Unit ] Item Specifications Rated voltageDC 12VOperating VoltageDC 9V - 16VOperating Temperature Range-30°C to 75°C Dark currentMax.
Components
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.
Inspection1.Turn the ignition switch OFF.2.Disconnect the intake actuator connector.3.Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4.Verify that the intake actuator operates to the recirculation position when connected in reverse.