| Inspection |
| 1. | There should be continuity between the No.17 and No.16 terminals when power and ground are connected to the No.17and No.19 in the ICM-B. |
| 1. | There should be continuity between the No.6 and No.8 terminals when power and ground are connected to the No.15and No.17in the ICM-B. |
DescriptionThe ICM is united with many kinds of relays and installed over the instrument panel box.
Inspection1.Turn the ignition switch OFF.2.Disconnect the temperature control actuator connector.3.Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.Verify that the temperature control actuator operates to the warm position when connected in reverse.
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.